Name Master Anamorphic
MA 35mm
T1.9
Master Anamorphic
MA 40mm
T1.9
Master Anamorphic
MA 50mm
T1.9
Master Anamorphic
MA 60mm
T1.9
Master Anamorphic
MA 75mm
T1.9
Master Anamorphic
MA 100mm
T1.9
             
Lens Mount (1) PL LDS PL LDS PL LDS PL LDS PL LDS PL LDS
Aperture T1.9 - T22 T1.9 - T22 T1.9 - T22 T1.9 - T22 T1.9 - T22 T1.9 - T22
Close Focus (2) 0.75m / 2'6" 0.70m / 2'4" 0.75m / 2'6" 0.90m / 3' 0.90 m / 3' 0.95 m / 3'1''
Magnification Ratio (3) H: 1:32.3,
V: 1:16.1
H: 1:25.6,
V: 1:12.8
H: 1:22.2,
V: 1:11.1
H: 1:24.3,
V: 1:12.2
H: 1:19.6,
V: 1:9.8
H: 1:14.7,
V: 1:7.4
Length (4) 183mm / 7.2" 183mm / 7.2" 183mm / 7.2" 183mm / 7.2" 183 mm / 7.2" 210 mm / 8.1''
Length (12) 235mm / 9.3" 235mm / 9.3" 235mm / 9.3" 235mm / 9.3" 235 mm / 9.3" 262 mm / 10.2''
Front Diameter (5) 95mm /
3.7"
95mm /
3.7"
95mm /
3.7"
95mm /
3.7"
95 mm /
3.7"
95 mm /
3.7"
Maximum Housing Diameter 114mm / 4.5" 114mm / 4.5" 114mm / 4.5" 114mm / 4.5" 114mm / 4.5" 114 mm / 4.5"
Weight 2,6kg /
5,7lbs
2,7kg /
6lbs
2,6kg /
5,7lbs
2,7kg /
6lbs
2,6kg /
5,7lbs
3,1kg /
6,8lbs
Entrance Pupil (6) -179mm/-7,04" -177mm / -6,96" -171mm / -6,75" 152mm / -5,99" -137mm / -5,38" -146mm / -5,74''
Angle of view H - V
Super 35 Cinemascope (8)
Image Diameter = 29,26mm (7)
65° - 30° 59° - 26° 48° - 21° 41° - 18° 33° - 14° 25° - 11°

(1) Lens Mount

Positive locking (PL) 54 mm stainless steel lens mount with Lens Data System (LDS) contacts

(2) Close Focus

Close focus is measured from the film/sensor plane

(3) Magnification ratio

Magnification ratio is the relationship of the size of an object on the film/sensor plane (first number) to the sizeof that object in real life (second number) at the close focus setting; Horizontal (H) and vertical (V)

(4) Length

Length is measured from the lens mount to the front of the lens housing

(5) Front Diameter

Diameter of the lens/matte box interface

(6) Entrance pupil

The distance from the entrance pupil to the film/sensor plane at focus = infinity. Positive numbers indicated an entrance pupil in front, negative numbers indicated an entrance pupil behind the film/sensor plane.The entrance pupil (often mistakenly called "nodal point") is the center of perspective; moving the camera/lens system around the center of the entrance pupil prevents parallax errors.

(7) Image Diameter

The image diameter (ID) is the diameter of the image circle needed for the respective format. These lenses are designed for the largest ID given here.

(8) Angle of view H, V, D (DIN Super 35)

Horizontal (H) and vertical (V) angles of view for a Super 35 Cinemascope camera aperture(dimensions 22,5mm x 18,7mm / 0.8858" x 0.7362")

(12) Length

Length is measured from the image to the front of the lens housing